{"id":111815,"date":"2026-04-29T14:00:55","date_gmt":"2026-04-29T13:00:55","guid":{"rendered":"https:\/\/stormagic.com\/?p=111815"},"modified":"2025-04-09T14:35:19","modified_gmt":"2025-04-09T13:35:19","slug":"svsan-data-sheet","status":"publish","type":"post","link":"https:\/\/stormagic.com\/de\/resources\/data-sheets\/svsan-data-sheet\/","title":{"rendered":"StorMagic SvSAN-Datenblatt"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-bottom:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1268.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;--awb-width-large:66.666666666667%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:2.88%;--awb-width-medium:66.666666666667%;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:2.88%;--awb-width-small:100%;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><h2>StorMagic SvSAN: Einfacher hyperkonvergenter Speicher<\/h2>\n<p>StorMagic SvSAN ist ein virtuelles SAN &#8211; eine softwaredefinierte L\u00f6sung, die auf zwei oder mehr Servern l\u00e4uft und hochverf\u00fcgbaren hyperkonvergenten Speicher liefert.<\/p>\n<p>SvSAN vereinfacht Ihre IT-Infrastruktur. Es beseitigt Ausfallzeiten, indem es die internen Rechen- und Speicherkapazit\u00e4ten jedes x86-Servers virtualisiert und \u00fcber einen Hypervisor als gemeinsamen Speicher bereitstellt.<\/p>\n<p>SvSAN bietet Datenverf\u00fcgbarkeit und -schutz mit nur zwei Servern, im Gegensatz zu anderen virtuellen SANs. Eine typische 2-Knoten-SVSAN-Konfiguration mit einer zentralisierten Verwaltungsschnittstelle und einem Zeugen ist unten abgebildet.<\/p>\n<p><img decoding=\"async\" class=\"lazyload\" src=\"https:\/\/stormagic.com\/wp-content\/uploads\/2021\/06\/Fig-1-SvSAN-2-node-with-containers-and-witness-01.png\" alt=\"SvSAN 2-Knoten mit Containern und Zeugen\" data-maxdpr=\"1.7\" \/><\/p>\n<p>Dieses SvSAN-Datenblatt ist in vier Abschnitte gegliedert, die sich mit den Funktionen von SvSAN, den Anforderungen, der Hardware- und Softwarekompatibilit\u00e4t und schlie\u00dflich den Supportstufen befassen.<\/p>\n<p>F\u00fcr eine genauere technische Untersuchung von StorMagic SvSAN, einschlie\u00dflich der Einsatzm\u00f6glichkeiten und Anwendungsf\u00e4lle, lesen Sie bitte das <a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/svsan-technical-overview\/\">Whitepaper SvSAN Technical Overview<\/a>.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-bg-color:#f4f4f4;--awb-bg-color-hover:#f4f4f4;--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:5.76%;--awb-width-medium:33.333333333333%;--awb-order-medium:0;--awb-spacing-right-medium:5.76%;--awb-spacing-left-medium:5.76%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-four\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h4 class=\"fusion-title-heading title-heading-center fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:24;line-height:1.5;\">Download das SvSAN-Datenblatt in Ihrer Sprache:<\/h4><\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-custom fusion-button-default button-1 fusion-button-default-span fusion-button-default-type fusion-has-button-gradient yellow-line\" style=\"--button_accent_color:#ffffff;--button_border_color:#ffffff;--button_accent_hover_color:#fedf00;--button_border_hover_color:#fedf00;--button_border_width-top:0px;--button_border_width-right:0px;--button_border_width-bottom:0px;--button_border_width-left:0px;--button_gradient_top_color:#4f4f4f;--button_gradient_bottom_color:#333333;--button_gradient_top_color_hover:#4f4f4f;--button_gradient_bottom_color_hover:#333333;--button_text_transform:uppercase;\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/data-sheet\/StorMagic-SvSAN-Data-Sheet.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">ENGLISCH<\/span><\/a><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-custom fusion-button-default button-2 fusion-button-default-span fusion-button-default-type fusion-has-button-gradient yellow-line\" style=\"--button_accent_color:#ffffff;--button_border_color:#ffffff;--button_accent_hover_color:#fedf00;--button_border_hover_color:#fedf00;--button_border_width-top:0px;--button_border_width-right:0px;--button_border_width-bottom:0px;--button_border_width-left:0px;--button_gradient_top_color:#4f4f4f;--button_gradient_bottom_color:#333333;--button_gradient_top_color_hover:#4f4f4f;--button_gradient_bottom_color_hover:#333333;--button_text_transform:uppercase;\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/data-sheet\/StorMagic-SvSAN-Data-Sheet-DE.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">DEUTSCH<\/span><\/a><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-custom fusion-button-default button-3 fusion-button-default-span fusion-button-default-type fusion-has-button-gradient yellow-line\" style=\"--button_accent_color:#ffffff;--button_border_color:#ffffff;--button_accent_hover_color:#fedf00;--button_border_hover_color:#fedf00;--button_border_width-top:0px;--button_border_width-right:0px;--button_border_width-bottom:0px;--button_border_width-left:0px;--button_gradient_top_color:#4f4f4f;--button_gradient_bottom_color:#333333;--button_gradient_top_color_hover:#4f4f4f;--button_gradient_bottom_color_hover:#333333;--button_text_transform:uppercase;\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/data-sheet\/StorMagic-SvSAN-Data-Sheet-ES.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">SPANISCH<\/span><\/a><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-custom fusion-button-default button-4 fusion-button-default-span fusion-button-default-type fusion-has-button-gradient yellow-line\" style=\"--button_accent_color:#ffffff;--button_border_color:#ffffff;--button_accent_hover_color:#fedf00;--button_border_hover_color:#fedf00;--button_border_width-top:0px;--button_border_width-right:0px;--button_border_width-bottom:0px;--button_border_width-left:0px;--button_gradient_top_color:#4f4f4f;--button_gradient_bottom_color:#333333;--button_gradient_top_color_hover:#4f4f4f;--button_gradient_bottom_color_hover:#333333;--button_text_transform:uppercase;\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/data-sheet\/StorMagic-SvSAN-Data-Sheet-HUN.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">HUNGARISCH<\/span><\/a><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"576\" height=\"814\" alt=\"StorMagic SvSAN Data Sheet\" title=\"StorMagic-SvSAN-Data-Sheet\" src=\"https:\/\/stormagic.com\/wp-content\/uploads\/2023\/08\/StorMagic-SvSAN-Data-Sheet.webp\" class=\"img-responsive wp-image-120367\" srcset=\"https:\/\/stormagic.com\/wp-content\/uploads\/2023\/08\/StorMagic-SvSAN-Data-Sheet-200x283.webp 200w, https:\/\/stormagic.com\/wp-content\/uploads\/2023\/08\/StorMagic-SvSAN-Data-Sheet-400x565.webp 400w, https:\/\/stormagic.com\/wp-content\/uploads\/2023\/08\/StorMagic-SvSAN-Data-Sheet.webp 576w\" sizes=\"(max-width: 640px) 100vw, 400px\" \/><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h2 class=\"fusion-title-heading title-heading-left fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:36;line-height:var(--awb-typography1-line-height);\">SvSAN&#8217;s Funktionen<\/h2><\/div><div class=\"fusion-text fusion-text-2\" style=\"--awb-text-transform:none;\"><p>StorMagic SvSAN verf\u00fcgt \u00fcber eine Reihe von Funktionen, die es dem Speicherarchitekten erm\u00f6glichen, das Beste aus seiner Infrastruktur herauszuholen. Diese Funktionen sind in der Tabelle unten auf dieser Seite detailliert aufgef\u00fchrt.<\/p>\n<p>Alle Funktionen, die f\u00fcr hochverf\u00fcgbaren gemeinsamen Speicher erforderlich sind, sind in einer SvSAN-Lizenz enthalten, einschlie\u00dflich des Zeugen. Dar\u00fcber hinaus sind zwei leistungssteigernde und sicherheitsf\u00f6rdernde Add-Ons verf\u00fcgbar, n\u00e4mlich die Caching- und Datenverschl\u00fcsselungsfunktionen von SvSAN. Viele dieser Funktionen werden in eigenen White Papers ausf\u00fchrlicher behandelt. <a href=\"https:\/\/stormagic.com\/resources\/white-papers\/\">Sehen Sie sich das gesamte Sortiment auf der StorMagic Website an.<\/a><\/p>\n<p>SvSAN bietet hochverf\u00fcgbaren hyperkonvergenten Speicher auf nur zwei Knoten unter Verwendung eines leichtgewichtigen Zeugen. Der SvSAN Witness verhindert Split-Brain-Szenarien in 2-Knoten-SVSAN-Clustern, indem er regelm\u00e4\u00dfig den Status jedes Knotens im Cluster \u00fcberpr\u00fcft. Die einzigen Daten, die zwischen dem Zeugen und den SvSAN-Knoten ausgetauscht werden, sind der &#8218;Heartbeat&#8216; &#8211; der Zeuge befindet sich nicht im Datenpfad. Dadurch kann es erhebliche Latenzzeiten und eine geringe Bandbreite tolerieren. Weitere Einzelheiten finden Sie im Datenblatt zu SvSAN Witness <a href=\"https:\/\/stormagic.com\/de\/resources\/data-sheets\/svsan-witness-data-sheet\/\" target=\"_blank\" rel=\"noopener\">hier<\/a>.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-3\" style=\"--awb-text-transform:none;\"><p>Zu den Caching-Funktionen von SvSAN geh\u00f6ren Write-Back- und Read-Ahead-Caching sowie Daten-Pinning. Diese Funktionen sind unter dem Namen Predictive Storage Caching bekannt und k\u00f6nnen die Speicherleistung eines Unternehmens drastisch verbessern, ohne dass erhebliche Investitionen in neue Hardware erforderlich sind.<\/p>\n<p>Die Datenverschl\u00fcsselungsfunktion von SvSAN erm\u00f6glicht es Unternehmen, die von SvSAN gespiegelten Daten zu verschl\u00fcsseln. Dadurch k\u00f6nnen gef\u00e4hrdete Standorte und die dort gespeicherten Daten gesch\u00fctzt werden. Sie ist FIPS 140-2-konform, macht teure L\u00f6sungen auf Betriebssystem- oder Hypervisor-Ebene \u00fcberfl\u00fcssig und ist mit jedem KMS kompatibel, das KMIP verwendet, einschlie\u00dflich StorMagics eigenem Key-Manager <a href=\"https:\/\/stormagic.com\/encryption-key-management\/\" target=\"_blank\" rel=\"noopener\">SvKMS<\/a>.<\/p>\n<p>StorMagic bietet einen kostenlosen Container Storage Interface (CSI)-Treiber f\u00fcr die Verwendung von Containern mit SvSAN. Dieser bietet persistenten, hochverf\u00fcgbaren Speicher f\u00fcr Kubernetes-orchestrierte Container-Implementierungen. SvSAN unterst\u00fctzt VMs, Container oder beides auf demselben 2-Knoten-Cluster. Ausf\u00fchrliche Informationen zu den Systemanforderungen und der Kompatibilit\u00e4t des CSI-Treibers sowie weitere Informationen zu dieser Bereitstellungsoption finden Sie im <a href=\"https:\/\/stormagic.com\/de\/resources\/data-sheets\/svsan-container-storage-interface-csi-driver-data-sheet\/\" target=\"_blank\" rel=\"noopener\">Datenblatt zum SvSAN Container Storage Interface Driver<\/a>.<\/p>\n<p>Die \u00dcberwachung und Verwaltung von SvSAN erfolgt \u00fcber StorMagic Edge Control. Diese Cloud-basierte Webkonsole kommuniziert mit allen SvSAN-Clustern eines Unternehmens \u00fcber eine VM, den so genannten Orchestrator, der sich im gleichen Unternehmensnetzwerk wie die SvSAN-Cluster befindet. Edge Control vereinfacht und zentralisiert die Verwaltung der SvSAN-Flotte und macht mehrere Tools oder Schnittstellen \u00fcberfl\u00fcssig. Weitere Informationen \u00fcber Edge Control, einschlie\u00dflich der Systemanforderungen f\u00fcr den Orchestrator, finden Sie im <a href=\"https:\/\/stormagic.com\/de\/resources\/data-sheets\/edge-control-data-sheet\/\">DatenblattEdge Control <\/a>.<\/p>\n<p>StorMagic SvSAN wird auf der Grundlage der nutzbaren VSA-Speicherkapazit\u00e4t lizenziert. Die Lizenzstufen sind auf 2TB, 6TB, 12TB, 24TB, 48TB und Unbegrenzte TB festgelegt.<\/p>\n<p>SvSAN ist als unbefristete Lizenz oder als Abonnement erh\u00e4ltlich. Nach einer einmaligen Zahlung k\u00f6nnen unbefristete SvSAN-Lizenzen f\u00fcr immer genutzt werden, wobei laufende Kosten nur f\u00fcr die Erneuerung des Supports anfallen. SvSAN-Abonnementlizenzen werden im Voraus f\u00fcr einen bestimmten Zeitraum, z.B. ein Jahr, bezahlt und dann nach Bedarf verl\u00e4ngert. Die Preisgestaltung basiert auf einer einzelnen SvSAN-Lizenz &#8211; die Anzahl der Knoten im Cluster bestimmt, wie viele Lizenzen erforderlich sind.<\/p>\n<p>F\u00fcr eine normale Bereitstellung mit 2 Knoten sind beispielsweise zwei SvSAN-Lizenzen erforderlich. Weitere Informationen finden Sie auf der <a href=\"https:\/\/stormagic.com\/svsan\/svsan-pricing\/\">Webseite mit den SvSAN-Preisen<\/a>.<\/p>\n<p>Eine kostenlose, voll funktionsf\u00e4hige Evaluierungsversion von SvSAN steht zum Download bereit. So k\u00f6nnen Unternehmen die Funktionen und Vorteile von SvSAN vor dem Kauf testen und erfahren.<\/p>\n<p>F\u00fcr weitere Informationen und zum Download einer Testversion besuchen Sie bitte: <a href=\"https:\/\/stormagic.com\/trial\/\">stormagic.com\/trial<\/a>.<\/p>\n<h2>Systemanforderungen<\/h2>\n<p>SvSAN hat sehr geringe Mindestanforderungen an die Hardware, die in der nebenstehenden Tabelle aufgef\u00fchrt sind.<\/p>\n<h4><strong>Systemvoraussetzungen f\u00fcr Witness<\/strong><\/h4>\n<p>Der Zeuge wird getrennt von den SvSAN-Knoten installiert und hat daher seine eigenen Mindestanforderungen in der nebenstehenden Tabelle. Der Zeuge sollte auf einem vom SvSAN VSA getrennten Server installiert werden.<\/p>\n<section id=\"hypervisor-compatibility\">\n<h2>Kompatibilit\u00e4t von Hardware und Software<\/h2>\n<p>SvSAN funktioniert mit jedem x86-Server, der auf der Hardwarekompatibilit\u00e4tsliste (HCL) von VMware vSphere ESXi oder Microsoft Hyper-V steht. Dar\u00fcber hinaus arbeitet SvSAN mit jedem unterst\u00fctzten internen Serverplattenspeicher oder JBOD-Array und unterst\u00fctzt dank seiner Software-RAID-F\u00e4higkeit auch Server ohne Hardware-RAID-Controller.<\/p>\n<h4><strong>Hypervisor-Unterst\u00fctzung<\/strong><\/h4>\n<p>SvSAN unterst\u00fctzt die Hypervisoren VMware vSphere und Microsoft Hyper-V. Es wird als Virtual Storage Appliance (VSA) installiert und ben\u00f6tigt nur minimale Serverressourcen, um den gemeinsamen Speicher bereitzustellen, der f\u00fcr die erweiterten Hypervisor-Funktionen erforderlich ist.<\/p>\n<p>SvSAN wird von den folgenden Versionen von VMware vSphere ESXi und Microsoft Windows Server\/Hyper-V Server unterst\u00fctzt.<\/p>\n<p>Wenn Sie sich f\u00fcr VMware vSphere als Hypervisor f\u00fcr die Implementierung von SvSAN entscheiden, empfiehlt StorMagic mindestens vSphere Essentials Plus, um hohe Verf\u00fcgbarkeit zu gew\u00e4hrleisten.<\/p>\n<h4><strong>Unterst\u00fctzung von VMware vCenter<\/strong><\/h4>\n<p>Mit seinem speziellen HTML5-Plugin kann SvSAN direkt von VMware vCenter aus verwaltet werden. SvSAN ist mit den Versionen von vCenter kompatibel, die Sie in der folgenden Tabelle finden.<\/p>\n<\/section>\n<\/div><div class=\"fusion-text fusion-text-4\"><h4><strong>VMware vCenter-Versionen, die mit SvSAN kompatibel sind:<\/strong><\/h4>\n<table>\n<tbody>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<td rowspan=\"2\"><strong>VMware vCenter Version<\/strong><\/td>\n<td colspan=\"4\"><strong>SvSAN-Version<\/strong><\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<td><strong>6.0<\/strong><\/td>\n<td><strong>6.1<\/strong><\/td>\n<td><strong>6.2<\/strong><\/td>\n<td><strong>6.3<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">VMware vCenter Server 8.0 &amp; Aktualisierungen<\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">VMware vCenter Server 7.0 &amp; Aktualisierungen<\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">VMware vCenter Server 6.7 &amp; Aktualisierungen<\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">VMware vCenter Server 6.5 &amp; Aktualisierungen<\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">VMware vCenter Server 6.0 &amp; Aktualisierungen<\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-padding-right:18px;--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:0%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:0%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-5\" style=\"--awb-text-transform:none;\"><h4><strong>StorMagic SvSAN Systemanforderungen:<\/strong><\/h4>\n<table>\n<tbody>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>Server<\/strong><\/td>\n<td style=\"vertical-align: top;\">2 Server erforderlich<br \/>\n&#8211; 3 optional f\u00fcr hohe Verf\u00fcgbarkeit bei Offline-Upgrades, Wartung, etc.<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>CPU<\/strong><\/td>\n<td style=\"vertical-align: top;\">1 x virtueller CPU-Kern<sup>1<\/sup><br \/>\n&#8211; 2GHz oder h\u00f6her reserviert<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>Speicher<\/strong><\/td>\n<td style=\"vertical-align: top;\">1GB RAM<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>Festplatte<\/strong><\/td>\n<td style=\"vertical-align: top;\">2 x virtuelle Speicherger\u00e4te, die von VSA verwendet werden<br \/>\n&#8211; 1 x 512MB Boot-Ger\u00e4t<br \/>\n&#8211; 1 x 20GB Journal Disk<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>Netzwerk<\/strong><\/td>\n<td style=\"vertical-align: top;\">1 x 1Gb Ethernet<br \/>\n&#8211; Mehrere Schnittstellen f\u00fcr Ausfallsicherheit erforderlich<br \/>\n&#8211; 10Gb Ethernet wird unterst\u00fctzt<br \/>\n&#8211; Jumbo Frames werden unterst\u00fctzt<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"footnote\"><sup>1<\/sup>WennSie die SvSAN-Datenverschl\u00fcsselung zur Verschl\u00fcsselung von Daten verwenden, werden 2+ virtuelle CPUs empfohlen<br \/>\n<sup>2<\/sup>Bei aktiviertem Caching kann zus\u00e4tzlicher RAM erforderlich sein<\/div>\n<\/div><div class=\"fusion-text fusion-text-6\" style=\"--awb-text-transform:none;\"><h4><strong>Anforderungen f\u00fcr Container<\/strong><\/h4>\n<p>Die folgenden Softwareversionen sind erforderlich, um Container auf StorMagic SvSAN einzusetzen:<\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<th scope=\"col\">Software<\/th>\n<th scope=\"col\">Version<\/th>\n<\/tr>\n<tr>\n<td>StorMagic SvSAN<\/td>\n<td>Ab 6.2 Update 5<\/td>\n<\/tr>\n<tr>\n<td>SvSAN CSI-Treiber<\/td>\n<td>1.0.0<\/td>\n<\/tr>\n<tr>\n<td>VMware vSphere<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td>Kubernetes<\/td>\n<td>1.19 oder 1.20<\/td>\n<\/tr>\n<tr>\n<td>VMware Tanzu Kubernetes Grid<sup>1<\/sup><\/td>\n<td>1.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"footnote\"><sup>1<\/sup>Optional- f\u00fcr die Ausf\u00fchrung von Kubernetes-Workloads nativ auf der Hypervisor-Ebene<\/div>\n<\/div><div class=\"fusion-text fusion-text-7\" style=\"--awb-text-transform:none;\"><h4 class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 24; line-height: 1.5;\" data-fontsize=\"24\" data-lineheight=\"36px\"><strong>SvSAN Zeugenanforderungen:<\/strong><\/h4>\n<table>\n<tbody>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>CPU<\/strong><\/td>\n<td style=\"vertical-align: top;\">1 x virtueller CPU-Kern (1 GHz)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>Speicher<\/strong><\/td>\n<td style=\"vertical-align: top;\">1GB (reserviert)<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>Datentr\u00e4ger<\/strong><\/td>\n<td style=\"vertical-align: top;\">1GB VMDK<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>Netzwerk<\/strong><\/td>\n<td style=\"vertical-align: top;\">1 x 1Gb Ethernet NIC<br \/>\nWenn Sie den Witness \u00fcber eine WAN-Verbindung verwenden, sollten Sie f\u00fcr einen optimalen Betrieb Folgendes beachten:<br \/>\n&#8211; Latenzzeit von weniger als 3000 ms, damit kann sich der Witness \u00fcberall auf der Welt befinden<br \/>\n&#8211; 9Kb\/s verf\u00fcgbare Netzwerkbandbreite zwischen VSA und Witness<\/td>\n<\/tr>\n<tr>\n<td style=\"vertical-align: top; background-color: #fedf00;\"><strong>Betriebssystem<\/strong><\/td>\n<td style=\"vertical-align: top;\">Der SvSAN Witness kann auf einem physischen Server oder einer virtuellen Maschine mit den folgenden Komponenten bereitgestellt werden:<br \/>\n&#8211; Windows Server 2019 und 2022 (64-bit)<br \/>\n&#8211; Hyper-V Server 2019 (64-bit)<br \/>\n&#8211; Raspbian Buster (32-bit)<br \/>\n&#8211; vCenter Server Appliance (vCSA)<sup>1<\/sup><br \/>\n&#8211; StorMagic SvSAN Witness Appliance<br \/>\n&#8211; Ubuntu 20.04<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"footnote\"><sup>1<\/sup>VMwarevSphere 6.7 und h\u00f6her<\/div>\n<\/div><div class=\"fusion-text fusion-text-8\" style=\"--awb-text-transform:none;\"><h4><strong>Hypervisoren, die mit SvSAN kompatibel sind:<\/strong><\/h4>\n<table class=\"compact-mobile-table\">\n<tbody>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<td colspan=\"2\" rowspan=\"2\"><strong>Hypervisor<\/strong><\/td>\n<td colspan=\"4\"><strong>SvSAN-Version<\/strong><\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<td><strong>6.0<\/strong><\/td>\n<td><strong>6.1<\/strong><\/td>\n<td><strong>6.2<\/strong><\/td>\n<td><strong>6.3<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"vertical-text\" style=\"vertical-align: top; background-color: #fedf00;\" rowspan=\"5\"><strong>VMware<\/strong><\/td>\n<td style=\"text-align: left;\">vSphere 8.0 und Aktualisierungen<sup>3<\/sup><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">vSphere 7.0 &amp; Updates<sup>2<\/sup><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">vSphere 6.7 &amp; Aktualisierungen<\/td>\n<td><\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">vSphere 6.5 &amp; Updates<sup>1<\/sup><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">vSphere 6.0 &amp; Aktualisierungen<\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<tr>\n<td class=\"vertical-text\" style=\"vertical-align: top; background-color: #fedf00;\" rowspan=\"5\"><strong>Microsoft<\/strong><\/td>\n<td style=\"text-align: left;\">Windows Server 2022<\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">Windows Server 2019<\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">Hyper-V Server 2019<\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">Windows Server 2016<\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">Hyper-V Server 2016<\/td>\n<td><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>&#8211;<\/strong><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"footnote\"><sup>1<\/sup>vSphere 6.5 Kompatibilit\u00e4t endet nach SvSAN 6.2 Update 2 Patch 3.<br \/>\n<sup>2<\/sup>vSphere 7.0 Kompatibilit\u00e4t ist ab SvSAN 6.2 Update 2 Patch 2 verf\u00fcgbar.<br \/>\n<sup>3<\/sup>vSphere 8.0 Kompatibilit\u00e4t ist ab SvSAN 6.3 Patch 1 verf\u00fcgbar.<\/div>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:30px;margin-bottom:30px;width:100%;\"><\/div><div class=\"fusion-text fusion-text-9\" style=\"--awb-text-transform:none;\"><h2>SvSAN Wartung &amp; Support<\/h2>\n<p>SvSAN Maintenance &amp; Support bietet Unternehmen Zugang zu den Support-Ressourcen von StorMagic, einschlie\u00dflich Produkt-Updates, Zugriff auf die Knowledgebase und E-Mail-Support durch unsere technischen Support-Mitarbeiter.<\/p>\n<p>Es sind zwei Stufen verf\u00fcgbar. Eine Zusammenfassung der beiden Stufen finden Sie in der Tabelle unten. Weitere Informationen zu SvSAN Maintenance &amp; Support finden Sie unter <a href=\"https:\/\/stormagic.com\/support\/\" target=\"_blank\" rel=\"noopener noreferrer\">stormagic.com\/support<\/a>.<\/p>\n<table class=\"compact-mobile-table\" style=\"text-align: left;\">\n<tbody>\n<tr style=\"background-color: #fedf00;\">\n<td><\/td>\n<td><strong>Gold-Unterst\u00fctzung<\/strong><\/td>\n<td><strong>Platin-Unterst\u00fctzung<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Betriebszeiten<\/strong><\/td>\n<td>8 Stunden pro Tag<sup>1<\/sup> (Mo &#8211; Fr)<\/td>\n<td>24 Stunden am Tag<sup>2<\/sup>, (7 Tage die Woche)<\/td>\n<\/tr>\n<tr>\n<td><strong>Dauer des Dienstes<\/strong><\/td>\n<td>1, 3 oder 5 Jahre<\/td>\n<td>1, 3 oder 5 Jahre<\/td>\n<\/tr>\n<tr>\n<td><strong>Produkt-Updates<\/strong><\/td>\n<td>Ja<\/td>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<td><strong>Produkt-Upgrades<\/strong><\/td>\n<td>Ja<\/td>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<td><strong>Zugriffsmethode<\/strong><\/td>\n<td>E-Mail<\/td>\n<td>E-Mail + Telefon (\u00fcber das Platin-Kontaktformular auf<br \/>\n<a class=\"break-word\" href=\"https:\/\/support.stormagic.com\" target=\"_self\" rel=\"noopener\">support.stormagic.com<\/a>)<\/td>\n<\/tr>\n<tr>\n<td><strong>Antwort-Methode<\/strong><\/td>\n<td>E-Mail + WebEx<\/td>\n<td>E-Mail + Telefon + WebEx<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximale Anzahl von Support-Administratoren pro Vertrag<\/strong><\/td>\n<td>2<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td><strong>Reaktionszeit<\/strong><\/td>\n<td>4 Stunden<\/td>\n<td>1 Stunde<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"footnote\"><sup>1<\/sup>Gold Support ist nur von 07:00 UTC\/DST bis 01:00 UTC\/DST verf\u00fcgbar. Wenn Ihre Gesch\u00e4ftszeiten au\u00dferhalb dieses Zeitfensters liegen, m\u00fcssen Sie den Platinum-Support erwerben.<br \/>\n<sup>2<\/sup>Globaler 24&#215;7-Support f\u00fcr Probleme des Schweregrads 1 &#8211; Kritischer Ausfall &amp; Schweregrad 2 &#8211; Degradiert<\/div>\n<\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:30px;margin-bottom:30px;width:100%;\"><\/div><div class=\"fusion-text fusion-text-10\" style=\"--awb-text-transform:none;\"><h2>SvSAN-Funktionstabelle<\/h2>\n<table>\n<tbody>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<td><strong>SvSAN-Merkmale<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Synchrone Spiegelung\/Hochverf\u00fcgbarkeit<\/strong><br \/>\n&#8211; Daten werden auf zwei SvSAN VSA-Knoten geschrieben, um die Betriebszeit des Dienstes zu gew\u00e4hrleisten<br \/>\n&#8211; Schreibvorg\u00e4nge werden nur abgeschlossen, wenn sie auf beiden SvSAN VSAs best\u00e4tigt wurden<br \/>\n&#8211; Im Falle eines Ausfalls werden Anwendungen auf andere verf\u00fcgbare Ressourcen umgestellt.<\/td>\n<\/tr>\n<tr>\n<td><strong>Unterst\u00fctzung von Stretched\/Metro-Clustern &#8211; <a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/creating-stretch-clusters-with-stormagic-svsan\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em>White Paper mit weiteren Informationen<\/em><\/a><\/strong><br \/>\n&#8211; Trennen Sie die Knoten geografisch, um eine zus\u00e4tzliche Ausfallsicherheit zu gew\u00e4hrleisten<br \/>\n&#8211; Verschiedene Racks, separate R\u00e4ume oder Geb\u00e4ude oder sogar eine ganze Stadt<\/td>\n<\/tr>\n<tr>\n<td><strong>Volume-Migration &#8211; <a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/stormagic-svsan-volume-migration-feature\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em>White Paper mit weiteren Informationen<\/em><\/a><\/strong><br \/>\n&#8211; Transparente und unterbrechungsfreie Migration von Volumes von einem Speicherort zu einem anderen<br \/>\n&#8211; Einfache und gespiegelte Volumes k\u00f6nnen zwischen Speicherpools auf demselben SvSAN VSA-Knoten oder zu einem ganz anderen SvSAN VSA-Knoten migriert werden<\/td>\n<\/tr>\n<tr>\n<td><strong>VMware Fault Tolerance<\/strong><br \/>\n&#8211; SvSAN auf dem VMware vSphere Hypervisor erm\u00f6glicht die Nutzung der Fault Tolerance-Funktion von VMware auf Clustern mit nur zwei Knoten<br \/>\n&#8211; Fault Tolerance-gesch\u00fctzte VMs haben keine Ausfallzeiten oder Serviceverluste, wenn ein Knoten offline geht<br \/>\n&#8211; Halten Sie kritische Anwendungen bei einem Knotenausfall online und in Betrieb<\/td>\n<\/tr>\n<tr>\n<td><strong>VSA-Wiederherstellung (nur VMware)<\/strong><br \/>\n&#8211; Automatisiert den Wiederherstellungsprozess eines SvSAN VSA-Knotens nach einem Serverausfall oder -austausch<br \/>\n&#8211; SvSAN VSA-Konfigurations\u00e4nderungen werden nachverfolgt und auf einem anderen SvSAN VSA im Cluster gespeichert<br \/>\n&#8211; Spiegelziele werden neu erstellt und neu synchronisiert, was eine schnelle R\u00fcckkehr zum optimalen Service erm\u00f6glicht<br \/>\n&#8211; Einfache Ziele k\u00f6nnen automatisch neu erstellt werden, bereit f\u00fcr die Datenwiederherstellung aus einem Backup<\/td>\n<\/tr>\n<tr>\n<td><strong>Unterst\u00fctzung der VMware vSphere Storage API (VAAI) (nur VMware)<\/strong><br \/>\n&#8211; Beschleunigung von VMware E\/A-Operationen durch Auslagerung an SvSAN<br \/>\n&#8211; Unterst\u00fctzung der Primitive Write Same, Atomic Test &amp; Set (ATS) und UNMAP<\/td>\n<\/tr>\n<tr>\n<td><strong>Edge Control zentrale \u00dcberwachung und Verwaltung der Flotte &#8211; <a href=\"https:\/\/stormagic.com\/svsan\/features\/edge-control\/\"><em>White Paper mit weiteren Informationen<\/em><\/a><\/strong><br \/>\n&#8211; StorMagic Edge Control erm\u00f6glicht Unternehmen die Verwaltung aller SvSAN-Cluster und VSAs von einem Bildschirm aus<br \/>\n&#8211; Edge Control ist eine cloudbasierte Konsole, auf die Sie \u00fcber einen beliebigen Webbrowser zugreifen k\u00f6nnen &#8211; \u00fcberwachen und verwalten Sie SvSAN von jedem Ort der Welt aus, der \u00fcber eine Internetverbindung verf\u00fcgt<br \/>\n&#8211; Nahtlose Integration durch ein spezielles Plugin f\u00fcr VMware vCenter ebenfalls verf\u00fcgbar<\/td>\n<\/tr>\n<tr>\n<td><strong>Witness &#8211; <a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/explaining-stormagic-svsan-witness\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em>White Paper mit weiteren Informationen<\/em><\/a><\/strong><br \/>\n&#8211; Dient als Quorum oder Tiebreaker und unterst\u00fctzt die Wahl der Cluster-F\u00fchrung, um &#8222;Split-Brain&#8220; zu verhindern<br \/>\n&#8211; Hunderte von Standorten k\u00f6nnen sich einen einzigen Witness teilen und er toleriert WAN-Verbindungen mit geringer Bandbreite und hoher Latenz<br \/>\n&#8211; Zu den unterst\u00fctzten Konfigurationen geh\u00f6ren lokaler Witness, Remote Shared Witness oder kein Witness<\/td>\n<\/tr>\n<tr>\n<td><strong>E\/A-Leistungsstatistiken<\/strong><br \/>\n&#8211; Bietet detaillierte, historische E\/A-Transaktions-, Durchsatz- und Latenzstatistiken f\u00fcr jedes Volume<br \/>\n&#8211; Einfache, intuitive grafische Darstellung mit Minimal-, Maximal- und Durchschnittswerten f\u00fcr t\u00e4gliche, monatliche und j\u00e4hrliche Zeitr\u00e4ume<br \/>\n&#8211; Die Daten k\u00f6nnen zur weiteren Analyse in CSV-Dateien exportiert werden.<\/td>\n<\/tr>\n<tr>\n<td><strong>Mehrere VSA-GUI-Bereitstellungen und -Upgrades<\/strong><br \/>\n&#8211; Bereitstellung und Upgrade von VSAs \u00fcber einen einzigen Assistenten, entweder sofort oder schrittweise f\u00fcr Aktivit\u00e4ten au\u00dferhalb der Gesch\u00e4ftszeiten<br \/>\n&#8211; SvSAN handhabt Abh\u00e4ngigkeiten und f\u00fchrt eine Zustandspr\u00fcfung durch, um sicherzustellen, dass es keine Auswirkungen auf die Umgebungen gibt.<\/td>\n<\/tr>\n<tr>\n<td><strong>PowerShell-Skripterstellung<\/strong><br \/>\n&#8211; Eins\u00e4tze \u00fcber viele Standorte hinweg k\u00f6nnen durch die Erstellung eines benutzerdefinierten PowerShell-Skripts abgewickelt werden.<\/td>\n<\/tr>\n<tr>\n<td><strong>Cluster-basierte Upgrades<\/strong><br \/>\n&#8211; Vereinfacht den Prozess des Upgrades mehrerer VSAs mit voller Kontrolle \u00fcber Datum\/Uhrzeit und wie viele\/welche Cluster aktualisiert werden sollen<br \/>\n&#8211; Upgrades k\u00f6nnen auf einem oder mehreren SvSAN VSAs gleichzeitig durchgef\u00fchrt werden, wodurch sichergestellt wird, dass der Speicher w\u00e4hrend der gesamten Zeit online bleibt<br \/>\n&#8211; Der automatisierte Prozess f\u00fchrt die Firmware aus, pr\u00fcft den Zustand des Clusters und f\u00e4hrt dann mit dem Upgrade jedes VSAs fort<\/td>\n<\/tr>\n<tr>\n<td><strong>Software RAID<\/strong><br \/>\n&#8211; Installieren Sie SvSAN auf Servern ohne Hardware-RAID-Controller, wie dem Lenovo SE350 und dem HPE Edgeline EL8000<br \/>\n&#8211; Konfigurieren Sie je nach Bedarf als RAID 0 (Striping) oder RAID 10<\/td>\n<\/tr>\n<tr>\n<td><strong>Container Storage Interface (CSI) Treiber<\/strong> &#8211; <a href=\"https:\/\/stormagic.com\/de\/resources\/data-sheets\/svsan-container-storage-interface-csi-driver-data-sheet\/\" target=\"_blank\" rel=\"noopener\"><strong><em>White Paper mit weiteren Informationen<\/em><\/strong><\/a><br \/>\n&#8211; Einfache Bereitstellung von Containern mit persistentem, hochverf\u00fcgbarem Speicher<br \/>\n&#8211; Keine zus\u00e4tzlichen Kosten f\u00fcr die Bereitstellung von Containern in einem SvSAN-Cluster<br \/>\n&#8211; Eine Plattform f\u00fcr VMs, Container oder beides<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<td><strong>Zus\u00e4tzliche Zusatzfunktionen verf\u00fcgbar<\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #d6d6d6;\">\n<td><strong>Predictive Read Ahead Caching (SSD und Speicher) &#8211; <a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/closing-the-performance-gap-svsan-caching\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em>White Paper mit weiteren Informationen<\/em><\/a><\/strong><br \/>\n&#8211; Vorteilhaft f\u00fcr sequentielle Lese-Workloads &#8211; f\u00fcllt den Speicher mit Daten, bevor sie angefordert werden<br \/>\n&#8211; Steigert die Leistung, indem weniger E\/A-Anfragen an die Festplatte gehen und stattdessen Daten aus dem Speicher mit geringer Latenz bereitgestellt werden<\/td>\n<\/tr>\n<tr style=\"background-color: #d6d6d6;\">\n<td><strong>Write-Back-Caching (SSD) &#8211; <a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/closing-the-performance-gap-svsan-caching\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em>White Paper mit weiteren Informationen<\/em><\/a><\/strong><br \/>\n&#8211; Nutzt SSDs, um die Leistung aller Schreibvorg\u00e4nge zu verbessern, indem die Latenzzeiten gesenkt und die effektiven IOPS erh\u00f6ht werden, was zu schnelleren Antwortzeiten f\u00fchrt, insbesondere bei zuf\u00e4lligen Schreibvorg\u00e4ngen<br \/>\n&#8211; Alle Schreib-E\/As werden an die SSD geleitet, so dass die Fertigstellung sofort an den Server zur\u00fcckgemeldet werden kann; zu einem sp\u00e4teren Zeitpunkt werden die Daten von der SSD auf die Festplatte geschrieben<\/td>\n<\/tr>\n<tr style=\"background-color: #d6d6d6;\">\n<td><strong>Data Pinning &#8211; <a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/closing-the-performance-gap-svsan-caching\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em>White Paper mit weiteren Informationen<\/em><\/a><\/strong><br \/>\n&#8211; Erm\u00f6glicht die dauerhafte Speicherung von Daten im Arbeitsspeicher und stellt so sicher, dass die Daten stets in der Cache-Ebene mit der h\u00f6chsten Leistung und der geringsten Latenz verf\u00fcgbar sind. Dies ist n\u00fctzlich f\u00fcr h\u00e4ufig wiederholte Vorg\u00e4nge wie das Booten virtueller Maschinen<br \/>\n&#8211; Intelligente Caching-Algorithmen identifizieren &#8222;hei\u00dfe&#8220; und &#8222;kalte&#8220; Daten und heben die &#8222;hei\u00dfen&#8220; Daten auf die Speicherebene mit der h\u00f6chsten Leistung und der geringsten Latenz (SSD oder Arbeitsspeicher).<\/td>\n<\/tr>\n<tr style=\"background-color: #d6d6d6;\">\n<td><strong>Datenverschl\u00fcsselung &#8211; <span id=\"page20R_mcid465\" class=\"markedContent\"> <\/span><a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/data-encryption-best-practices-edge-environments\/\" target=\"_blank\" rel=\"noopener\"><em><span id=\"page20R_mcid466\" class=\"markedContent\"><span dir=\"ltr\">White Paper mit weiteren Informationen<\/span><\/span><\/em><\/a><\/strong><br \/>\n&#8211; Verwendet einen FIPS 140-2-konformen Algorithmus (XTS-AES-256) zur Verschl\u00fcsselung aller von SvSAN verwalteten Daten oder nur ausgew\u00e4hlter Volumes<br \/>\n&#8211; Erm\u00f6glicht sicheres L\u00f6schen und erneutes Verschl\u00fcsseln<br \/>\n&#8211; Kompatibel mit jedem KMIP-kompatiblen System Key-Management einschlie\u00dflich <a href=\"https:\/\/stormagic.com\/encryption-key-management\/\">StorMagic SvKMS<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1268.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-three\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h3 class=\"fusion-title-heading title-heading-center fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:32;line-height:1.1;\">Download das SvSAN-Datenblatt in Ihrer Sprache:<\/h3><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_5 1_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:20%;--awb-margin-top-large:0px;--awb-spacing-right-large:9.6%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:9.6%;--awb-width-medium:20%;--awb-order-medium:0;--awb-spacing-right-medium:9.6%;--awb-spacing-left-medium:9.6%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-5 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/data-sheet\/StorMagic-SvSAN-Data-Sheet.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">ENGLISCH<\/span><\/a><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_5 1_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:20%;--awb-margin-top-large:0px;--awb-spacing-right-large:9.6%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:9.6%;--awb-width-medium:20%;--awb-order-medium:0;--awb-spacing-right-medium:9.6%;--awb-spacing-left-medium:9.6%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-6 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/data-sheet\/StorMagic-SvSAN-Data-Sheet-DE.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">DEUTSCH<\/span><\/a><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_5 1_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:20%;--awb-margin-top-large:0px;--awb-spacing-right-large:9.6%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:9.6%;--awb-width-medium:20%;--awb-order-medium:0;--awb-spacing-right-medium:9.6%;--awb-spacing-left-medium:9.6%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-7 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/data-sheet\/StorMagic-SvSAN-Data-Sheet-ES.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">SPANISCH<\/span><\/a><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_5 1_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:20%;--awb-margin-top-large:0px;--awb-spacing-right-large:9.6%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:9.6%;--awb-width-medium:20%;--awb-order-medium:0;--awb-spacing-right-medium:9.6%;--awb-spacing-left-medium:9.6%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-8 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/data-sheet\/StorMagic-SvSAN-Data-Sheet-HUN.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">HUNGARISCH<\/span><\/a><\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":13,"featured_media":130337,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":"","_links_to":"","_links_to_target":""},"categories":[4],"tags":[444,118,107,124],"class_list":["post-111815","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-sheets","tag-data-sheet","tag-hyperconverged","tag-svsan","tag-virtualized-storage","product-svsan"],"acf":[],"_links":{"self":[{"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/posts\/111815","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/comments?post=111815"}],"version-history":[{"count":0,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/posts\/111815\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/media\/130337"}],"wp:attachment":[{"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/media?parent=111815"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/categories?post=111815"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/tags?post=111815"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}