{"id":112671,"date":"2018-11-30T16:41:02","date_gmt":"2018-11-30T16:41:02","guid":{"rendered":"https:\/\/stormagic.com\/?p=112671"},"modified":"2026-07-15T21:48:32","modified_gmt":"2026-07-15T20:48:32","slug":"stormagic-svsan-with-lenovo-thinksystem-servers","status":"publish","type":"post","link":"https:\/\/stormagic.com\/de\/resources\/data-sheets\/stormagic-svsan-with-lenovo-thinksystem-servers\/","title":{"rendered":"StorMagic SvSAN mit Lenovo ThinkSystem Servern"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1268.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-blend:overlay;--awb-bg-size:cover;--awb-width-large:66.666666666667%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:2.88%;--awb-width-medium:66.666666666667%;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:2.88%;--awb-width-small:100%;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\" style=\"--awb-text-transform:none;\"><h2 class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 50; line-height: 1.1;\" data-fontsize=\"50\" data-lineheight=\"55px\">Zukunftsweisende Server-Hardware, die die Speicherung am Netzwerkrand vereinfacht<\/h2>\n<p style=\"font-size: 20px;\" data-fusion-font=\"true\">Eine effiziente, kosteng\u00fcnstige Speicherl\u00f6sung, die flexibel mit der Nachfrage skaliert werden kann, ist ein Ziel, das alle Unternehmen anstreben sollten. Niemand sollte mehr als n\u00f6tig f\u00fcr seine Speicherinfrastruktur und deren laufenden Betrieb und Wartung bezahlen, unabh\u00e4ngig von seinen Leistungsanforderungen. Vor diesem Hintergrund haben StorMagic und Lenovo eine Partnerschaft geschlossen, um eine Reihe von L\u00f6sungen f\u00fcr kostenbewusste Speicherarchitekten anzubieten, die keine Kompromisse bei der Leistung eingehen und Hyperkonvergenz erm\u00f6glichen. Dieses Datenblatt beschreibt diese L\u00f6sungen, die die Lenovo ThinkSystem Rack-Server zusammen mit StorMagic SvSAN nutzen.<\/p>\n<h3 class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 30; line-height: 1.17;\" data-fontsize=\"30\" data-lineheight=\"35.1px\">Hohe Leistung ohne hohe Kosten<\/h3>\n<p style=\"font-size: 20px;\" data-fusion-font=\"true\">Die Partnerschaft zwischen StorMagic und Lenovo deckt alle ThinkSystem Rack-Server von Lenovo ab. Dieses Datenblatt befasst sich jedoch mit den drei am h\u00e4ufigsten genutzten Modellen. Die gemeinsame L\u00f6sung kombiniert die bekannte Serverleistung und Zuverl\u00e4ssigkeit von Lenovo mit der hohen Verf\u00fcgbarkeit und Einfachheit von StorMagic SvSAN. Die beiden liefern eine Komplettl\u00f6sung, die kosteng\u00fcnstigen, leichtgewichtigen Speicher bietet und daher ideal f\u00fcr Edge Computing und entfernte Standorte oder den Einsatz in kleinen und mittleren Rechenzentren geeignet ist.<\/p>\n<h3 class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 30; line-height: 1.17;\" data-fontsize=\"30\" data-lineheight=\"35.1px\">Zukunftsweisende Server-Hardware<\/h3>\n<p style=\"font-size: 20px;\" data-fusion-font=\"true\">ThinkSystem Server sind speziell daf\u00fcr konzipiert, Leistung, Sicherheit und Flexibilit\u00e4t in einer offenen Umgebung zu bieten, die die M\u00f6glichkeiten in der Zukunft nicht einschr\u00e4nken wird. Da die Entwicklungen in den Bereichen IoT und k\u00fcnstliche Intelligenz die Belastung der IT-Infrastruktur au\u00dferhalb des Rechenzentrums wahrscheinlich erh\u00f6hen werden, ben\u00f6tigen Unternehmen Hardware, die den neuen Herausforderungen gewachsen ist. Lenovo Rack-Server bieten einen un\u00fcbertroffenen Wert, Flexibilit\u00e4t und branchenf\u00fchrende Effizienz, um gesch\u00e4ftskritische Anforderungen mit legend\u00e4rer Qualit\u00e4t und Zuverl\u00e4ssigkeit zu erf\u00fcllen.<\/p>\n<p><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Entdecken Sie die ThinkSystem Produktpalette von Lenovo im Detail auf der <\/span><a style=\"font-size: 20px;\" href=\"https:\/\/www.lenovo.com\/us\/en\/servers-storage\/\" target=\"_blank\" rel=\"noopener noreferrer\" data-fusion-font=\"true\">Lenovo Website<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\">.<\/span><\/p>\n<h3 class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 30; line-height: 1.17;\" data-fontsize=\"30\" data-lineheight=\"35.1px\">Vereinfachung der Speicherung \u201cat the Edge\u201d<\/h3>\n<p><span style=\"font-size: 20px;\" data-fusion-font=\"true\">SvSAN ist das virtuelle SAN, das die komplexe Welt der virtualisierten Speicherung einfach macht. Die Technologie ist ideal f\u00fcr Edge-Computing-Umgebungen und basiert auf softwaredefiniertem Speicher, der physische SANs \u00fcberfl\u00fcssig macht. SvSAN ist so konzipiert, dass es sehr einfach zu installieren und zu verwalten ist, unabh\u00e4ngig davon, ob es als Teil einer hyperkonvergenten L\u00f6sung oder als reines Speicherziel f\u00fcr einen beliebigen Lenovo Server eingesetzt wird. SvSAN hat sehr geringe Anforderungen an die Systemhardware, eine zentralisierte Verwaltung\/Einrichtung und einen <\/span><a style=\"font-size: 20px;\" href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/explaining-stormagic-svsan-witness\/\" target=\"_blank\" rel=\"noopener noreferrer\" data-fusion-font=\"true\">unglaublich leichtgewichtigen Zeugen<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\">, der Verbindungen mit geringer Bandbreite und hoher Latenz toleriert und vollst\u00e4ndig vom Server-Cluster getrennt ist. Der Witness erm\u00f6glicht die Erstellung echter hochverf\u00fcgbarer 2-Knoten-Cluster oder 3-Knoten-Cluster, die einen Offline-Server aufgrund eines Ausfalls oder einer Wartung verkraften und dennoch hochverf\u00fcgbar bleiben k\u00f6nnen.<\/span><\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-padding-right:20px;--awb-padding-bottom:20px;--awb-padding-left:20px;--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:5.76%;--awb-width-medium:33.333333333333%;--awb-order-medium:0;--awb-spacing-right-medium:5.76%;--awb-spacing-left-medium:5.76%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-four\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h4 class=\"fusion-title-heading title-heading-center fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:24;line-height:1.5;\">Laden Sie die StorMagic SvSAN mit Lenovo ThinkSystem Servern L\u00f6sungs\u00fcbersicht herunter:<\/h4><\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-1 fusion-button-default-span fusion-button-default-type yellow-line\" style=\"--button_text_transform:uppercase;\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/solution-brief\/Stormagic-SvSAN-with-Lenovo-ThinkSystem-Solution-Brief-DE.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">HERUNTERLADEN<\/span><\/a><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div class=\"fusion-image-element\" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"188\" height=\"300\" title=\"Datenbla\u0308tter\" src=\"https:\/\/stormagic.com\/wp-content\/uploads\/2026\/07\/Datenblaetter-188x300.jpg\" alt class=\"img-responsive wp-image-131810\" srcset=\"https:\/\/stormagic.com\/wp-content\/uploads\/2026\/07\/Datenblaetter-200x319.jpg 200w, https:\/\/stormagic.com\/wp-content\/uploads\/2026\/07\/Datenblaetter-400x638.jpg 400w, https:\/\/stormagic.com\/wp-content\/uploads\/2026\/07\/Datenblaetter-600x957.jpg 600w, https:\/\/stormagic.com\/wp-content\/uploads\/2026\/07\/Datenblaetter-800x1277.jpg 800w, https:\/\/stormagic.com\/wp-content\/uploads\/2026\/07\/Datenblaetter-1200x1915.jpg 1200w, https:\/\/stormagic.com\/wp-content\/uploads\/2026\/07\/Datenblaetter.jpg 1410w\" sizes=\"(max-width: 640px) 100vw, 400px\" \/><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-2\" style=\"--awb-text-transform:none;\"><p style=\"font-size: 20px;\" data-fusion-font=\"true\">Die folgende Tabelle zeigt die Mindestanforderungen an die Hardware von SvSAN:<\/p>\n<table>\n<tbody style=\"padding-right: 25px; padding-left: 25px; vertical-align: top;\">\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"color: var(--awb-color1); font-size: 18px;\" data-fusion-font=\"true\">CPU<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1 x virtueller CPU-Kern<\/span><sup><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1<\/span><\/sup><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n\u2022 2GHz oder h\u00f6her reserviert<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"color: var(--awb-color1); font-size: 18px;\" data-fusion-font=\"true\">Arbeitsspeicher<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1GB arbeitsspeicher<\/span><sup><span style=\"font-size: 18px;\" data-fusion-font=\"true\">2<\/span><\/sup><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"color: var(--awb-color1); font-size: 18px;\" data-fusion-font=\"true\">Festplatte<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">2 x virtuelle Speicherger\u00e4te, die von VSA verwendet werden<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n\u2022 1 x 512MB Boot-Ger\u00e4t<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n\u2022 1 x 20GB Journal-Diskette<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"color: var(--awb-color1); font-size: 18px;\" data-fusion-font=\"true\">Network<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1 x 1Gb-Ethernet<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n\u2022 Unterst\u00fctzung mehrerer Schnittstellen, die f\u00fcr die<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n\u2022 Ausfallsicherheit von 10-Gb-Eternet erforderlich sind<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n\u2022 Unterst\u00fctzte Jumbo-Frames<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup><span style=\"font-size: 20px;\" data-fusion-font=\"true\">1<\/span><\/sup><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Bei Verwendung der SvSAN-Datenverschl\u00fcsselung werden 2+ virtuelle CPUs empfohlen<\/span><br \/>\n<span style=\"font-size: 20px;\" data-fusion-font=\"true\"><br \/>\n<\/span><sup><span style=\"font-size: 20px;\" data-fusion-font=\"true\">2<\/span><\/sup><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Zus\u00e4tzliche Arbeitsspeicher (RAM) k\u00f6nnen erforderlich sein, wenn die Zwischenspeicherungsfunktion aktiviert ist<\/span><\/p>\n<p style=\"font-size: 20px;\" data-fusion-font=\"true\">SvSAN wird auf der Grundlage der nutzbaren VSA-Kapazit\u00e4t (Virtual Storage Appliance) lizenziert. Die Lizenzstufen sind auf 2TB, 6TB, 12TB und unbegrenzte TB festgelegt. SvSAN-Lizenzen sind unbefristet &#8211; nach einer einmaligen Zahlung k\u00f6nnen sie f\u00fcr immer genutzt werden. Die einzigen laufenden Kosten sind die Zahlungen f\u00fcr die Verl\u00e4ngerung des Supports.<\/p>\n<p><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Alle Funktionen, die f\u00fcr hochverf\u00fcgbaren gemeinsamen Speicher erforderlich sind, sind in einer SvSAN-Lizenz enthalten. Dar\u00fcber hinaus sind zwei leistungs- und sicherheitssteigernde Add- Ons verf\u00fcgbar, n\u00e4mlich die Caching- und Datenverschl\u00fcsselungsfunktionen von SvSAN. Alle Funktionen von SvSAN, einschlie\u00dflich Caching und Verschl\u00fcsselung, k\u00f6nnen Sie auf der <\/span><a style=\"font-size: 20px;\" href=\"\/de\/\" data-fusion-font=\"true\">StorMagic-Website<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\"> n\u00e4her kennenlernen.<\/span><\/p>\n<p><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Die Datenverschl\u00fcsselungsfunktion von SvSAN erm\u00f6glicht es Unternehmen, die von SvSAN gespiegelten Daten zu verschl\u00fcsseln. Dadurch k\u00f6nnen gef\u00e4hrdete Edge-Sites und die darin enthaltenen Daten gesch\u00fctzt werden. Es ist FIPS 140-2-konform, macht teure L\u00f6sungen auf Betriebssystem- oder Hypervisor-Ebene \u00fcberfl\u00fcssig und ist mit jedem KMS kompatibel, das KMIP verwendet, einschlie\u00dflich StorMagics eigenem Schl\u00fcsselmanager <\/span><a style=\"font-size: 20px;\" href=\"https:\/\/stormagic.com\/de\/encryption-key-management\/\" data-fusion-font=\"true\">SvKMS<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\">.<\/span><\/p>\n<table>\n<tbody>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<td><strong style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Funktionen des SvSAN<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong style=\"font-size: 20px;\" data-fusion-font=\"true\">Synchrone Spiegelung\/hohe Verf\u00fcgbarkeit<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Erweiterter\/Metro-Clustersupport &#8211; <\/span><a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/creating-stretch-clusters-with-stormagic-svsan\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Whitepaper mit weiteren Informationen<\/span><\/em><\/a><\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Datenvolumen-Migration &#8211; <\/span><a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/stormagic-svsan-volume-migration-feature\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Whitepaper mit weiteren Informationen<\/span><\/em><\/a><\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong style=\"font-size: 20px;\" data-fusion-font=\"true\">VSA-Wiederherstellung (nur VMware)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong style=\"font-size: 20px;\" data-fusion-font=\"true\">VMware vSphere Storage API (VAAI)-Support (NUR VMware)<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong style=\"font-size: 20px;\" data-fusion-font=\"true\">Zentralisierte \u00dcberwachung und Verwaltung<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Remote-Witness (Neutraler Speicher-Host) &#8211; <\/span><a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/explaining-stormagic-svsan-witness\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Whitepaper mit weiteren Informationen<\/span><\/em><\/a><\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong style=\"font-size: 20px;\" data-fusion-font=\"true\">I\/O-Performancestatistik<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong style=\"font-size: 20px;\" data-fusion-font=\"true\">Bereitstellung und Upgrade auf Mehreren VSA GUIs<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong style=\"font-size: 20px;\" data-fusion-font=\"true\">Powershell-Skripterstellung<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr style=\"text-align: center; background-color: #fedf00;\">\n<td><strong style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Zus\u00e4tzliche Zusatzfunktionen Verf\u00fcgbar<\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #d6d6d6;\">\n<td><strong><span style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Predictive read-ahead-caching (SSD und Speicher) &#8211; <\/span><a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/closing-the-performance-gap-svsan-caching\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em><span style=\"font-size: 20px; color: var(--awb-custom14);\" data-fusion-font=\"true\">Whitepaper mit weiteren Informationen<\/span><\/em><\/a><\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #d6d6d6;\">\n<td><strong><span style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Write back caching (SSD) &#8211; <\/span><a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/closing-the-performance-gap-svsan-caching\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em><span style=\"font-size: 20px; color: var(--awb-custom14);\" data-fusion-font=\"true\">Whitepaper mit weiteren Informationen<\/span><\/em><\/a><\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #d6d6d6;\">\n<td><strong><span style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Daten-Pinning &#8211; <\/span><a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/closing-the-performance-gap-svsan-caching\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em><span style=\"font-size: 20px; color: var(--awb-custom14);\" data-fusion-font=\"true\">Whitepaper mit weiteren Informationen<\/span><\/em><\/a><\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #d6d6d6;\">\n<td><strong><span style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Datenverschl\u00fcsselung &#8211; <\/span><a href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/data-encryption-best-practices-edge-environments\/\" rel=\"noopener noreferrer\"><em><span style=\"font-size: 20px; color: var(--awb-custom12);\" data-fusion-font=\"true\">Datenblatt mit weiteren Informationen<\/span><\/em><\/a><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 20px;\" data-fusion-font=\"true\">\u00a0<\/span><\/p>\n<p><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Weitere Einzelheiten zu den Funktionen, M\u00f6glichkeiten und Anforderungen von SvSAN finden Sie im <\/span><a style=\"font-size: 20px;\" href=\"https:\/\/stormagic.com\/de\/resources\/data-sheets\/svsan-data-sheet\/\" target=\"_blank\" rel=\"noopener noreferrer\" data-fusion-font=\"true\">Produktdatenblatt<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\"> und im <\/span><a style=\"font-size: 20px;\" href=\"https:\/\/stormagic.com\/de\/resources\/white-papers\/svsan-technical-overview\/\" target=\"_blank\" rel=\"noopener noreferrer\" data-fusion-font=\"true\">White Paper mit dem technischen \u00dcberblick<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\">.<\/span><\/p>\n<h3 class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 30; line-height: 1.17; font-size: 20px;\" data-fontsize=\"30\" data-lineheight=\"35.1px\" data-fusion-font=\"true\">H\u00e4ufig gesehene Eins\u00e4tze<\/h3>\n<p style=\"font-size: 20px;\" data-fusion-font=\"true\">Die drei in der folgenden Tabelle aufgef\u00fchrten Servermodelle sind die am h\u00e4ufigsten mit SvSAN eingesetzten Server aus der Lenovo ThinkSystem Reihe. SvSAN ist jedoch mit allen Lenovo-Servern kompatibel, was dem Speicherarchitekten eine gro\u00dfe Bandbreite an M\u00f6glichkeiten bietet.<\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr style=\"background-color: #fedf00;\">\n<td><\/td>\n<td style=\"width: 28%;\"><strong style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Lenovo SR250<\/strong><\/td>\n<td style=\"width: 28%;\"><strong style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Lenovo SR530<\/strong><\/td>\n<td style=\"width: 28%;\"><strong style=\"font-size: 20px; color: var(--awb-color1);\" data-fusion-font=\"true\">Lenovo SR650<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><\/td>\n<td><img decoding=\"async\" class=\"alignnone\" src=\"https:\/\/stormagic.com\/wp-content\/uploads\/2018\/11\/ThinkSystem-SR250.png\" alt=\"Lenovo SR250\" width=\"725\" height=\"515\" \/><\/td>\n<td><img decoding=\"async\" class=\"alignnone\" src=\"https:\/\/stormagic.com\/wp-content\/uploads\/2018\/11\/ThinkSystem-SR530.png\" alt=\"Lenovo SR530\" width=\"725\" height=\"515\" \/><\/td>\n<td><img decoding=\"async\" class=\"alignnone\" src=\"https:\/\/stormagic.com\/wp-content\/uploads\/2018\/11\/ThinkSystem-SR650.png\" alt=\"Lenovo SR650\" width=\"725\" height=\"515\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong><span style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">\u00dc<\/span><span style=\"color: var(--awb-color1); font-size: 18px;\" data-fusion-font=\"true\">bersicht<\/span><\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Der Lenovo ThinkSystem SR250 ist ein Einprozessor-Rackserver, der Leistung, Zuverl\u00e4ssigkeit, Flexibilit\u00e4t und Sicherheit in einem kompakten 1U-Formfaktor f\u00fcr kleine bis mittelgro\u00dfe Unternehmen vereint.<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\nGesch\u00e4ft. Der SR250 bietet ein hervorragendes Preis-Leistungs-Verh\u00e4ltnis mit einer Kombination aus hoher Rechenleistung und Zuverl\u00e4ssigkeit mit Intel\u00ae Xeon\u00ae E-2100 Prozessoren der n\u00e4chsten Generation und Unterst\u00fctzung f\u00fcr eine Reihe von Speicherkonfigurationen.<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Der Lenovo ThinkSystem SR530 ist ein idealer 1U-Rackserver mit 2 Sockeln f\u00fcr kleine Unternehmen bis hin zu Gro\u00dfunternehmen, die branchenf\u00fchrende Zuverl\u00e4ssigkeit, Verwaltung und Sicherheit sowie kostenoptimierte Leistung und Flexibilit\u00e4t f\u00fcr zuk\u00fcnftiges Wachstum ben\u00f6tigen.<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">F\u00fcr mittlere bis gro\u00dfe Unternehmen und Anbieter von Managed- und Cloud-Services ist das Lenovo ThinkSystem SR650 der optimale 2U-Server mit zwei Sockeln &#8211; der weltweit am h\u00e4ufigsten verwendete Servertyp.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Beispiel Einsatz<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Abgelegene Kliniken mit geringen Hardwareanforderungen, die jedoch hochverf\u00fcgbare Anwendungen f\u00fcr die Patientenversorgung und eine sichere Speicherung von Patientendaten ben\u00f6tigen.<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Fertigungsanlagen, f\u00fcr die Anlagenbetrieb, Maschinendatenerfassung und IoT-Ger\u00e4te hohe Verf\u00fcgbarkeit und Echtzeitverarbeitung erfordern.<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Einzelhandelskunden mit vielen Anwendungen in den Gesch\u00e4ften, wie z.B. Point of Sale, Bestandsverfolgung, Kundenanalyse und Video\u00fcberwachung.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Formfaktor\/H\u00f6he<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1U Rack, H\u00f6he: 43mm, Breite: 434.6mm, Tiefe: 497.8mm (19.6&#8220;)<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1U Rack<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">2U Rack Server<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Prozessor (max)\/Cache (max)<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1-Sockel Intel\u00ae Xeon\u00ae E-2100 Prozessoren, bis zu 6 Kerne bei 95W<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 2x Intel\u00ae Xeon\u00ae Platinum Prozessoren, bis zu 125W<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 2x Intel\u00ae Xeon\u00ae Platinum Prozessoren, bis zu 205W<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Arbeitsspeicher<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 64GB 2666MHz TruDDR4 ECC UDIMMs (4 Steckpl\u00e4tze)<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 768GB in 12x Steckpl\u00e4tzen, mit 64GB DIMMs 2666MHz TruDDR4<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 3TB* in 24x Steckpl\u00e4tzen, mit 128GB* DIMMs; 2666MHz TruDDR4<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n*1.5TB bei GA; 128GB DIMMs in K\u00fcrze verf\u00fcgbar. Erh\u00e4ltlich vor der GA \u00fcber ein Sonderangebot.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Erweiterungssteckpl\u00e4tze<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1 x 16-Lane oder 2x 8-Lane PCIe 3.0 Steckpl\u00e4tze 4-Lane PCIe Gen3, x8 interner RAID Steckplatz<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 3x PCIe 3.0, \u00fcber mehrere Riser-Optionen (entweder nur PCIe oder PCIe und ML2)<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 7x PCIe 3.0 \u00fcber mehrere Riser-Optionen, darunter 1x dedizierter PCIe-Steckplatz f\u00fcr RAID-Adapter<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Laufwerkssch\u00e4chte<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">4x 3,5&#8220; SATA-Laufwerke mit einfacher oder Hot-Swap-Funktion<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n4x 2,5&#8220; SATA\/SAS-Laufwerke mit einfachem Wechselmechanismus<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n10x 2.5&#8220; Hot-Swap SATA\/ SAS\/ SSD Laufwerke<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\n8x 2,5&#8220; Hot-Swap SATA\/SAS\/SSD-Laufwerke + 2x 2,5&#8220; NVMe-Laufwerk<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 8 Buchten. SFF: 8x HS SAS\/SATA; oder LFF: 4x HS SAS\/SATA; oder 4x Simple-Swap (SS) SATA; PLUS bis zu 2x gespiegeltes M.2-Boot (opt. RAID 1)<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Bis zu 24 HS-Einsch\u00fcbe (inkl. 4 oder 8 AnyBay): plus bis zu 2x gespiegelter M.2-Boot (opt. RAID 1)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">HBA\/RAID-Unterst\u00fctzung<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Software-RAID unterst\u00fctzt einfachen Swap und Hot Swap<\/span><br \/>\n<span style=\"font-size: 18px;\" data-fusion-font=\"true\"><br \/>\nMehrere RAID-Konfigurationen (gemeinsam mit ThinkSystem)<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Software RAID std. (bis zu 8 Anschl\u00fcsse); opt. Hardware-RAID (bis zu 8 Ports) mit Flash-Cache; HBAs mit bis zu 8 Ports<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Hardware-RAID (bis zu 24 Ports) mit Flash-Cache; HBAs mit bis zu 16 Ports<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Funktionen f\u00fcr Sicherheit und Verf\u00fcgbarkeit<\/strong><\/td>\n<td><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">TPM 1.2\/2.0; PFA; HS\/redundante Laufwerke und PSUs; Betriebstemperatur bis zu 45\u00b0C (mit Einschr\u00e4nkungen); Front-Access-Diagnose \u00fcber dedizierten USB-Anschluss<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">TPM 1.2\/2.0; PFA; HS\/redundante Laufwerke, L\u00fcfter und PSUs; 45\u00b0C Dauerbetrieb; Lichtpfad-Diagnose-LEDs; Front-Access-Diagnose \u00fcber dedizierten USB-Anschluss<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Netzwerkschnittstelle<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">2x 1GbE-Ports eingebettet, 1x 1GbE dediziertes Management<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">2x 1GbE Ports + 1x dedizierter 1GbE Management Port (standardm\u00e4\u00dfig); optionales modulares LOM unterst\u00fctzt 2x 1GbE Base-T oder 2x 10GbE mit Base-T oder SFP+<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">2\/4-Port 1GbE LOM; 2\/4-Port 10GbE LOM (Base-T oder SFP+); 1x dedizierter 1GbE-Management-Port<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Strom<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Festes Netzteil 300W Gold, doppelt redundant AC (450W, Platin)<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">2x Hot-Swap\/redundant (Energy Star 2.1): 550W\/750W 80 PLUS Platinum; oder 750W 80 PLUS Titanium<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">2x Hot-Swap\/redundant: 550W\/750W\/1100W\/1600W 80 PLUS Platinum; oder 750W 80 PLUS Titanium<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Verwaltung der Systeme<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Lenovo XClarity, Administrator mit mobiler Option, optional National Z TPM 2.0<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">XClarity Controller eingebettetes Management, XClarity Administrator zentralisierte Infrastrukturbereitstellung, XClarity Integrator Plugins und XClarity Energy Manager zentralisiertes Server-Energiemanagement<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">XClarity Controller eingebettetes Management, XClarity Administrator zentralisierte Infrastrukturbereitstellung, XClarity Integrator Plugins und XClarity Energy Manager zentralisiertes Server-Energiemanagement<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px; color: var(--awb-color1);\" data-fusion-font=\"true\">Unterst\u00fctzte Betriebssysteme<\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Microsoft, Red Hat, SUSE und VMware ESXi<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Microsoft Windows Server, SLES, RHEL, VMware vSphere. Besuchen Sie lenovopress.com\/osig f\u00fcr weitere Informationen.<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere. Besuchen Sie lenovopress.com\/osig f\u00fcr weitere Informationen.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #fedf00;\"><strong style=\"font-size: 18px;\" data-fusion-font=\"true\"><span style=\"color: var(--awb-color1);\">B<\/span><span style=\"color: var(--awb-color1);\">egrenzte Garantie<\/span><\/strong><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1 Jahr oder 3 Jahre Garantie<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1- und 3-Jahres-Service f\u00fcr austauschbare Ger\u00e4te und Vor-Ort-Service, 9&#215;5 am n\u00e4chsten Arbeitstag, optional. Service-Upgrades<\/span><\/td>\n<td><span style=\"font-size: 18px;\" data-fusion-font=\"true\">1- und 3-Jahres-Service f\u00fcr austauschbare Ger\u00e4te und Vor-Ort-Service, 9&#215;5 am n\u00e4chsten Arbeitstag, optional. Service-Upgrades<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div class=\"fusion-text fusion-text-3\" style=\"--awb-text-transform:none;\"><h3 class=\"fusion-responsive-typography-calculated\" style=\"--fontsize: 30; line-height: 1.17;\" data-fontsize=\"30\" data-lineheight=\"35.1px\">Weitere Informationen und n\u00e4chste Schritte<\/h3>\n<p><span style=\"font-size: 20px;\" data-fusion-font=\"true\">Auf der <\/span><a style=\"font-size: 20px;\" href=\"https:\/\/www.lenovo.com\/us\/en\/servers-storage\/\" target=\"_blank\" rel=\"noopener noreferrer\" data-fusion-font=\"true\">Lenovo Website<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\"> finden Sie eine F\u00fclle von Informationen zu den ThinkSystem Servern, einschlie\u00dflich einzelner Datenbl\u00e4tter f\u00fcr jedes Servermodell. Ebenso verf\u00fcgt StorMagic \u00fcber eine <\/span><a style=\"font-size: 20px;\" href=\"\/de\/?page_id=109988\" target=\"_blank\" rel=\"noopener noreferrer\" data-fusion-font=\"true\">Bibliothek mit Dokumentation<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\"> zu SvSAN, darunter Installationsanleitungen, White Papers und Datenbl\u00e4tter.<\/span><\/p>\n<p><span style=\"font-size: 20px;\" data-fusion-font=\"true\">StorMagic SvSAN ist auf der weltweiten Preisliste von Lenovo verf\u00fcgbar, so dass jeder Lenovo-Vertriebsmitarbeiter oder -H\u00e4ndler eine Serverkonfiguration mit SvSAN erstellen kann. Die Kombination von Lenovo Servern mit SvSAN Software war noch nie so einfach. Dar\u00fcber hinaus ist das Lenovo-Team bei StorMagic bereit, Informationen und Unterst\u00fctzung zur Partnerschaft und ihren M\u00f6glichkeiten zu geben. Senden Sie einfach eine E-Mail an <\/span><a style=\"font-size: 20px;\" href=\"mailto:sales@stormagic.com\" data-fusion-font=\"true\">sales@stormagic.com<\/a><span style=\"font-size: 20px;\" data-fusion-font=\"true\">, um uns zu erreichen.<\/span><\/p>\n<\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-three\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h3 class=\"fusion-title-heading title-heading-center fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:32;line-height:1.1;\">Laden Sie die SvSAN &amp; HPE Edgeline L\u00f6sungs\u00fcbersicht im PDF-Format herunter:<\/h3><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;\"><\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-2 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"\/pdf\/solution-brief\/Stormagic-SvSAN-with-Lenovo-ThinkSystem-Solution-Brief-DE.pdf\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">HERUNTERLADEN<\/span><\/a><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":13,"featured_media":131802,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":"","_links_to":"","_links_to_target":""},"categories":[4,34],"tags":[89,443,107],"class_list":["post-112671","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-sheets","category-lenovo","tag-lenovo","tag-solution-brief","tag-svsan","product-svsan"],"acf":[],"_links":{"self":[{"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/posts\/112671","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/comments?post=112671"}],"version-history":[{"count":8,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/posts\/112671\/revisions"}],"predecessor-version":[{"id":131828,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/posts\/112671\/revisions\/131828"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/media\/131802"}],"wp:attachment":[{"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/media?parent=112671"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/categories?post=112671"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/stormagic.com\/de\/wp-json\/wp\/v2\/tags?post=112671"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}